#General information ITEM section %ITEM SERIAL NUMBER 20220900200388 Mfr serial number STN39429-00388 #Test information Test seciton %TEST TEST DATE (DD/MM/YYYY) 12/07/2000 PROBLEM NO PASSED YES Run number 20220900200388 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.13884 I_LEAK350V (microA) 0.2094 Substr Origin 033 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 288 Vdep (V) 90 R Bias Upper (MOhm) 1.77 R Bias Lower (MOhm) 1.36 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole 346 Pinhole 368 Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 45.7 20 63.49 30 74.35 40 82.72 50 89.93 60 96.33 70 102.23 80 107.67 90 112.64 100 117.37 110 121.91 120 126.29 130 130.57 140 134.74 150 138.84 160 142.84 170 146.59 180 150.6 190 154.4 200 158.2 210 161.91 220 165.57 230 169.18 240 172.74 250 176.29 260 179.78 270 183.2 280 186.5 290 189.9 300 193.2 310 196.5 320 199.8 330 203 340 206.2 350 209.4 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2921.86 35 2591.77 40 2343.85 45 2149.94 50 1997.24 55 1870.56 60 1764.95 65 1674.4 70 1597.14 75 1533.8 80 1486.05 85 1455.02 90 1437.03 95 1427.53 100 1422.63 105 1419.91 110 1418.2 115 1416.99 120 1415.88 #End of manufacturer data file