#General information ITEM section %ITEM SERIAL NUMBER 20220900200432 Mfr serial number STN39513-00432 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 27/07/2000 PROBLEM NO PASSED YES Run number 20220900200432 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.1312 I_LEAK350V (microA) 0.1928 Substr Origin 035 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 288 Vdep (V) 80 R Bias Upper (MOhm) 1.49 R Bias Lower (MOhm) 1.32 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 47.1 20 65.3 30 75.21 40 82.7 50 89.29 60 94.89 70 99.64 80 104.02 90 108.1 100 112.32 110 116.28 120 120.13 130 123.9 140 127.59 150 131.2 160 134.74 170 138.17 180 141.6 190 144.94 200 148.28 210 151.51 220 154.69 230 157.85 240 160.96 250 164.01 260 166.99 270 169.91 280 172.9 290 175.86 300 178.76 310 181.7 320 184.5 330 187.3 340 190.1 350 192.8 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2638.2 35 2342.05 40 2117.26 45 1944.9 50 1808.13 55 1695.06 60 1601.97 65 1526.57 70 1472.42 75 1440.39 80 1424.15 85 1416.69 90 1413.11 95 1410.96 100 1409.43 105 1408.29 110 1407.43 115 1406.62 120 1405.88 #End of manufacturer data file