#General information ITEM section %ITEM SERIAL NUMBER 20220900200462 Mfr serial number STN39515-00462 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 27/07/2000 PROBLEM NO PASSED YES Run number 20220900200462 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.13938 I_LEAK350V (microA) 0.2144 Substr Origin 039 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 287 Vdep (V) 80 R Bias Upper (MOhm) 1.5 R Bias Lower (MOhm) 1.19 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole 254 Pinhole 271 Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 44.56 20 62.65 30 72.87 40 80.8 50 88.15 60 95.03 70 101.04 80 106.5 90 111.61 100 116.55 110 121.32 120 125.96 130 130.52 140 134.97 150 139.38 160 143.72 170 147.89 180 151.8 190 156.18 200 160.26 210 164.25 220 168.18 230 172.08 240 175.97 250 179.81 260 183.7 270 187.3 280 190.9 290 194.3 300 197.5 310 201 320 204.4 330 207.8 340 211.1 350 214.4 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2720.8 35 2413.67 40 2181.79 45 2001.3 50 1859.41 55 1742.26 60 1645.5 65 1565.03 70 1502.64 75 1461.04 80 1437.31 85 1425.77 90 1420.42 95 1417.56 100 1415.79 105 1414.46 110 1413.6 115 1412.58 120 1411.91 #End of manufacturer data file