#General information ITEM section %ITEM SERIAL NUMBER 20220900200484 Mfr serial number STN39515-00484 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 27/07/2000 PROBLEM NO PASSED YES Run number 20220900200484 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.12445 I_LEAK350V (microA) 0.1883 Substr Origin 037 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 286 Vdep (V) 75 R Bias Upper (MOhm) 1.5 R Bias Lower (MOhm) 1.19 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open 394 Open 396 Open 398 %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 41.92 20 58.18 30 67.28 40 74.23 50 80.12 60 85.99 70 91.24 80 96 90 100.48 100 104.83 110 108.98 120 112.98 130 116.87 140 120.71 150 124.45 160 128.12 170 131.65 180 135.23 190 138.74 200 142.2 210 145.62 220 148.97 230 152.25 240 155.49 250 158.67 260 161.81 270 164.85 280 167.9 290 170.95 300 173.93 310 176.88 320 179.75 330 182.5 340 185.5 350 188.3 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2638.98 35 2342.5 40 2117.8 45 1943.88 50 1806.43 55 1693.15 60 1600.54 65 1527 70 1476.04 75 1447.18 80 1433.26 85 1427.02 90 1423.64 95 1421.62 100 1420.17 105 1418.99 110 1418.19 115 1417.27 120 1416.5 #End of manufacturer data file