#General information ITEM section %ITEM SERIAL NUMBER 20220900200524 Mfr serial number SRN39691-00524 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 07/08/2000 PROBLEM NO PASSED YES Run number 20220900200524 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.12599 I_LEAK350V (microA) 0.15158 Substr Origin 016 Substr Orient 100 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 288 Vdep (V) 75 R Bias Upper (MOhm) 1.49 R Bias Lower (MOhm) 1.18 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 47.93 20 69.34 30 79.83 40 87.2 50 93.06 60 98.03 70 102.42 80 106.21 90 109.72 100 112.96 110 116.04 120 118.63 130 121.15 140 123.6 150 125.99 160 128.17 170 130.17 180 132.15 190 134 200 135.73 210 137.32 220 138.8 230 140.11 240 141.52 250 142.75 260 143.92 270 144.99 280 146.01 290 146.96 300 147.87 310 148.75 320 149.51 330 150.23 340 150.93 350 151.58 #CV 10 15 O.L. 20 O.L. 25 2822.94 30 2462.32 35 2209.67 40 2017.94 45 1867.63 50 1746.65 55 1645.69 60 1561.42 65 1492.97 70 1445.31 75 1419.42 80 1407.75 85 1402.87 90 1400.58 95 1399.23 100 1398.25 105 1397.62 110 1397.09 115 1396.58 120 1396.23 #End of manufacturer data file