#General information ITEM section %ITEM SERIAL NUMBER 20220900200558 Mfr serial number SRN39692-00558 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 26/08/00 PROBLEM NO PASSED YES Run number 20220900200558 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.11331 I_LEAK350V (microA) 0.14703 Substr Origin 040 Substr Orient 100 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 80 R Bias Upper (MOhm) 1.44 R Bias Lower (MOhm) 1.36 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 42.78 20 61.83 30 71.02 40 77.55 50 82.79 60 87.09 70 90.81 80 94.17 90 97.29 100 100.24 110 103.34 120 105.93 130 108.45 140 110.82 150 113.31 160 115.62 170 117.82 180 120.03 190 122.16 200 124.24 210 126.17 220 128.04 230 129.92 240 131.75 250 133.5 260 135.16 270 136.73 280 138.23 290 139.7 300 141.1 310 142.45 320 143.69 330 144.89 340 145.99 350 147.03 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2632.9 35 2355 40 2145.59 45 1982.11 50 1851.25 55 1742.04 60 1650.53 65 1572.35 70 1507.7 75 1460.57 80 1432.88 85 1420.17 90 1414.74 95 1412.2 100 1410.72 105 1409.75 110 1409.04 115 1408.46 120 1407.98 #End of manufacturer data file