#General information ITEM section %ITEM SERIAL NUMBER 20220900200622 Mfr serial number STN39517-00622 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 02/08/2000 PROBLEM NO PASSED YES Run number 20220900200622 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.10451 I_LEAK350V (microA) 0.15908 Substr Origin 042 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 80 R Bias Upper (MOhm) 1.79 R Bias Lower (MOhm) 1.32 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short 63 Short 64 Short 66 Short 67 Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 36.14 20 49.54 30 56.87 40 62.7 50 67.81 60 72.43 70 76.48 80 80.38 90 84.06 100 87.69 110 91.22 120 94.65 130 98 140 101.28 150 104.51 160 107.68 170 110.75 180 113.83 190 116.8 200 119.73 210 122.66 220 125.52 230 128.36 240 131.17 250 133.92 260 136.72 270 139.4 280 142.08 290 144.73 300 147.37 310 149.96 320 152.22 330 154.34 340 156.83 350 159.08 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2722.2 35 2417.47 40 2187.16 45 2009.77 50 1868.82 55 1752.2 60 1655.52 65 1574.53 70 1509.96 75 1464.34 80 1436.63 85 1422.35 90 1415.52 95 1411.99 100 1409.9 105 1408.39 110 1407.3 115 1406.35 120 1405.48 #End of manufacturer data file