#General information ITEM section %ITEM SERIAL NUMBER 20220900201020 Mfr serial number SRN10146-01020 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 06/11/2000 PROBLEM NO PASSED YES Run number 20220900201020 #Test data Data section %DATA TEMPERATURE (C) 25 I_LEAK150V (microA) 0.11049 I_LEAK350V (microA) 0.14079 Substr Origin 049 Substr Orient 100 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 288 Vdep (V) 65 R Bias Upper (MOhm) 1.41 R Bias Lower (MOhm) 1.22 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 39.53 20 56.69 30 66.03 40 72.9 50 78.3 60 82.74 70 86.64 80 90.24 90 93.63 100 96.84 110 99.43 120 103.01 130 105.5 140 108.06 150 110.49 160 112.78 170 114.84 180 116.99 190 117.84 200 120.64 210 122.39 220 124.14 230 125.72 240 127.25 250 128.75 260 130.17 270 131.54 280 132.86 290 134.1 300 135.33 310 136.52 320 137.64 330 138.73 340 139.76 350 140.79 #CV 10 15 O.L. 20 2998.85 25 2512.06 30 2196.12 35 1972.48 40 1805.26 45 1673.57 50 1568.41 55 1487.28 60 1435.61 65 1410.08 70 1399.68 75 1395.52 80 1393.34 85 1392.01 90 1391.02 95 1390.34 100 1389.72 105 1389.19 110 1388.74 115 1388.44 120 1387.96 #End of manufacturer data file