#General information ITEM section %ITEM SERIAL NUMBER 20220900201286 Mfr serial number SRN10577-01286 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 14/12/2000 PROBLEM NO PASSED YES Run number 20220900201286 #Test data Data section %DATA TEMPERATURE (C) 25 I_LEAK150V (microA) 0.1832 I_LEAK350V (microA) 0.2439 Substr Origin 052 Substr Orient 100 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 284 Vdep (V) 50 R Bias Upper (MOhm) 1.8 R Bias Lower (MOhm) 1.42 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 54.46 20 81.26 30 97.56 40 109.07 50 118.43 60 126.93 70 134.82 80 142.18 90 149.11 100 155.63 110 161.81 120 167.77 130 173.22 140 178.4 150 183.2 160 187.8 170 192.1 180 196.1 190 200.1 200 203.9 210 207.4 220 210.8 230 214.1 240 217.1 250 220.1 260 222.8 270 225.6 280 228.2 290 230.7 300 233.1 310 235.4 320 237.7 330 239.8 340 241.9 350 243.9 #CV 10 15 O.L. 20 2546.47 25 2121.48 30 1851.81 35 1662.09 40 1529.18 45 1450.63 50 1417.58 55 1406.24 60 1401.77 65 1399.43 70 1397.91 75 1396.68 80 1395.71 85 1394.96 90 1394.24 95 1393.62 100 1393.05 105 1392.5 110 1392.05 115 1391.58 120 1391.31 #End of manufacturer data file