#General information ITEM section %ITEM SERIAL NUMBER 20220900201291 Mfr serial number SRN10577-01291 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 14/12/2000 PROBLEM NO PASSED YES Run number 20220900201291 #Test data Data section %DATA TEMPERATURE (C) 25 I_LEAK150V (microA) 0.2131 I_LEAK350V (microA) 0.278 Substr Origin 052 Substr Orient 100 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 284 Vdep (V) 50 R Bias Upper (MOhm) 1.8 R Bias Lower (MOhm) 1.42 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 67.38 20 98.31 30 116.31 40 129.3 50 140.08 60 149.94 70 158.93 80 167.47 90 175.55 100 182.9 110 190 120 196.4 130 202.2 140 207.8 150 213.1 160 218 170 222.6 180 227 190 231.3 200 235.2 210 239 220 242.7 230 246.1 240 249.4 250 252.6 260 255.6 270 258.5 280 261.3 290 263.9 300 266.5 310 268.9 320 271.4 330 273.6 340 275.8 350 278 #CV 10 15 O.L. 20 2501.08 25 2080.65 30 1815.02 35 1629.94 40 1507.32 45 1445.37 50 1423.82 55 1416.6 60 1413.42 65 1411.43 70 1409.96 75 1408.89 80 1407.93 85 1407.07 90 1406.47 95 1405.83 100 1405.3 105 1404.67 110 1404.24 115 1403.95 120 1403.47 #End of manufacturer data file