#General information ITEM section %ITEM SERIAL NUMBER 20220900201297 Mfr serial number SRN10577-01297 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 14/12/2000 PROBLEM NO PASSED YES Run number 20220900201297 #Test data Data section %DATA TEMPERATURE (C) 25 I_LEAK150V (microA) 0.17899 I_LEAK350V (microA) 0.245 Substr Origin 052 Substr Orient 100 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 282 Vdep (V) 50 R Bias Upper (MOhm) 1.8 R Bias Lower (MOhm) 1.42 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 57.36 20 84.8 30 99.55 40 110.06 50 118.69 60 126.42 70 133.74 80 140.51 90 146.99 100 153.05 110 158.89 120 164.35 130 169.44 140 174.27 150 178.99 160 183.3 170 187.6 180 191.7 190 195.6 200 199.4 210 203 220 206.5 230 209.8 240 212.9 250 216 260 218.9 270 221.7 280 224.5 290 227 300 229.5 310 232 320 234.5 330 237.1 340 240.3 350 245 #CV 10 15 O.L. 20 2564.35 25 2130.22 30 1855.42 35 1663.03 40 1531.97 45 1460.03 50 1432.58 55 1423.25 60 1419.31 65 1417.13 70 1415.59 75 1414.32 80 1413.41 85 1412.49 90 1411.74 95 1411.15 100 1410.53 105 1409.94 110 1409.51 115 1409.02 120 1408.55 #End of manufacturer data file