#General information ITEM section %ITEM SERIAL NUMBER 20220900201307 Mfr serial number SRN10577-01307 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 14/12/2000 PROBLEM NO PASSED YES Run number 20220900201307 #Test data Data section %DATA TEMPERATURE (C) 25 I_LEAK150V (microA) 0.2291 I_LEAK350V (microA) 0.2886 Substr Origin 052 Substr Orient 100 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 279 Vdep (V) 50 R Bias Upper (MOhm) 1.8 R Bias Lower (MOhm) 1.42 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 73.96 20 110.19 30 130.21 40 144.75 50 156.52 60 166.79 70 176.14 80 184.6 90 192.5 100 199.8 110 206.7 120 213 130 218.6 140 224 150 229.1 160 233.8 170 238.3 180 242.4 190 246.4 200 250.1 210 253.7 220 257 230 260.2 240 263.2 250 266.1 260 268.9 270 271.5 280 274 290 276.4 300 278.6 310 280.8 320 282.9 330 284.9 340 286.8 350 288.6 #CV 10 15 O.L. 20 2527.82 25 2103.25 30 1835.12 35 1648.33 40 1523.79 45 1458.6 50 1434.9 55 1427.03 60 1423.63 65 1421.57 70 1420.15 75 1419.02 80 1418.1 85 1417.29 90 1416.57 95 1415.97 100 1415.42 105 1414.94 110 1414.47 115 1414.13 120 1413.64 #End of manufacturer data file