#General information ITEM section %ITEM SERIAL NUMBER 20220900201772 Mfr serial number STN11020-01772 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 26/03/2001 PROBLEM NO PASSED YES Run number 20220900201772 #Test data Data section %DATA TEMPERATURE (C) 23 I_LEAK150V (microA) 0.3261 I_LEAK350V (microA) 0.5325 Substr Origin 064 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 75 R Bias Upper (MOhm) 1.52 R Bias Lower (MOhm) 1.3 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole 131 Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 86.07 20 130.87 30 162.1 40 180.2 50 193.7 60 211.8 70 224.1 80 235.8 90 249.4 100 264.3 110 279.5 120 292.1 130 301.1 140 315.7 150 326.1 160 336.7 170 345.2 180 358.3 190 370.4 200 383.3 210 395.4 220 407.9 230 412.8 240 424.8 250 433.9 260 445.1 270 452.3 280 463.2 290 474.2 300 486.1 310 499.2 320 505.7 330 518.3 340 525.8 350 532.5 #CV 10 15 O.L. 20 O.L. 25 2926.22 30 2522.72 35 2241.13 40 2029.75 45 1866.35 50 1736.51 55 1630.72 60 1548.49 65 1490.99 70 1456.84 75 1439.18 80 1430.66 85 1426.42 90 1423.99 95 1422.38 100 1421.12 105 1419.8 110 1418.78 115 1418.4 120 1417.36 #End of manufacturer data file