#General information ITEM section %ITEM SERIAL NUMBER 20220900201794 Mfr serial number STN11021-01794 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 28/03/2001 PROBLEM NO PASSED YES Run number 20220900201794 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.09089 I_LEAK350V (microA) 0.13461 Substr Origin 066 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 55 R Bias Upper (MOhm) 1.61 R Bias Lower (MOhm) 1.37 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 29.57 20 41.43 30 47.3 40 51.72 50 55.84 60 60.27 70 64.68 80 68.68 90 72.41 100 75.83 110 79.04 120 82.29 130 85.21 140 88.04 150 90.89 160 93.51 170 96.13 180 98.7 190 101.14 200 103.55 210 105.93 220 108.22 230 110.49 240 112.69 250 114.95 260 117.02 270 119.18 280 121.28 290 123.26 300 125.3 310 127.25 320 129.08 330 130.95 340 132.74 350 134.61 #CV 10 15 O.L. 20 2885.43 25 2376.36 30 2053.49 35 1826.33 40 1663.5 45 1548.6 50 1479.56 55 1445.05 60 1430.21 65 1423.67 70 1420.21 75 1417.95 80 1416.21 85 1414.74 90 1413.49 95 1412.4 100 1411.41 105 1410.53 110 1409.76 115 1408.97 120 1408.32 #End of manufacturer data file