#General information ITEM section %ITEM SERIAL NUMBER 20220900201824 Mfr serial number STN11018-01824 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 28/03/2001 PROBLEM NO PASSED YES Run number 20220900201824 #Test data Data section %DATA TEMPERATURE (C) 25 I_LEAK150V (microA) 0.11602 I_LEAK350V (microA) 0.1962 Substr Origin 063 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 291 Vdep (V) 60 R Bias Upper (MOhm) 1.44 R Bias Lower (MOhm) 1.26 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 18.092 20 52.57 30 59.84 40 65.46 50 70.45 60 75.48 70 80.6 80 85.63 90 90.48 100 95.02 110 99.38 120 103.55 130 107.8 140 111.98 150 116.02 160 120.08 170 123.89 180 127.76 190 131.75 200 135.83 210 139.62 220 143.42 230 147.3 240 151.69 250 155.3 260 159.23 270 163.28 280 167.95 290 171.78 300 175.22 310 179.4 320 184.9 330 187.6 340 191.57 350 196.2 #CV 10 15 O.L. 20 2947.06 25 2425.53 30 2095 35 1861.92 40 1693.44 45 1570.43 50 1492.68 55 1452.42 60 1435.02 65 1427.57 70 1423.86 75 1421.42 80 1419.59 85 1418.06 90 1416.75 95 1415.58 100 1414.6 105 1413.68 110 1412.85 115 1412.15 120 1411.39 #End of manufacturer data file