#General information ITEM section %ITEM SERIAL NUMBER 20220900203404 Mfr serial number STN11530-03404 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 25/06/2001 PROBLEM NO PASSED YES Run number 20220900203404 #Test data Data section %DATA TEMPERATURE (C) 25 I_LEAK150V (microA) 0.13745 I_LEAK350V (microA) 0.214 Substr Origin 103 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 60 R Bias Upper (MOhm) 1.69 R Bias Lower (MOhm) 1.52 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole 642 Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 42.41 20 61.45 30 71.22 40 78.51 50 84.61 60 90.62 70 96.56 80 102.39 90 107.98 100 113.44 110 118.56 120 123.51 130 128.29 140 132.93 150 137.45 160 141.89 170 146.24 180 150.51 190 154.66 200 158.78 210 162.85 220 166.85 230 170.78 240 174.68 250 178.5 260 182.1 270 185.7 280 189.4 290 193 300 196.6 310 200.1 320 203.6 330 207.1 340 210.6 350 214 #CV 10 15 O.L. 20 O.L. 25 2531.49 30 2182.88 35 1941.21 40 1758.86 45 1621.64 50 1527.16 55 1472.33 60 1446.94 65 1436.21 70 1431.12 75 1428.1 80 1425.93 85 1424.26 90 1422.77 95 1421.57 100 1420.43 105 1419.54 110 1418.71 115 1417.9 120 1417.15 #End of manufacturer data file