#General information ITEM section %ITEM SERIAL NUMBER 20220900203407 Mfr serial number STN11530-03407 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 25/06/2001 PROBLEM NO PASSED YES Run number 20220900203407 #Test data Data section %DATA TEMPERATURE (C) 25 I_LEAK150V (microA) 0.13272 I_LEAK350V (microA) 0.2002 Substr Origin 103 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 65 R Bias Upper (MOhm) 1.69 R Bias Lower (MOhm) 1.52 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 44.69 20 63.81 30 73.51 40 80.73 50 86.64 60 92.1 70 97.49 80 102.68 90 107.58 100 112.17 110 116.56 120 120.79 130 124.94 140 128.93 150 132.72 160 136.72 170 140.53 180 144.26 190 147.91 200 151.54 210 155.1 220 158.61 230 162.08 240 165.49 250 168.84 260 172.18 270 175.53 280 178.78 290 181.9 300 185 310 188 320 191.1 330 194.1 340 197.2 350 200.2 #CV 10 15 O.L. 20 O.L. 25 2642.66 30 2277.2 35 2023.84 40 1832.23 45 1684.67 50 1573.77 55 1498.2 60 1456.83 65 1437.57 70 1429.24 75 1425.19 80 1422.68 85 1420.91 90 1419.46 95 1418.26 100 1417.18 105 1416.29 110 1415.54 115 1414.81 120 1414.04 #End of manufacturer data file