#General information ITEM section %ITEM SERIAL NUMBER 20220900203422 Mfr serial number STN11534-03422 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 27/06/2001 PROBLEM NO PASSED YES Run number 20220900203422 #Test data Data section %DATA TEMPERATURE (C) 25 I_LEAK150V (microA) 0.12364 I_LEAK350V (microA) 0.1882 Substr Origin 104 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 288 Vdep (V) 60 R Bias Upper (MOhm) 1.45 R Bias Lower (MOhm) 1.27 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 39.54 20 56.85 30 65.46 40 71.88 50 77.2 60 82.46 70 88.14 80 93.48 90 98.43 100 103.08 110 107.48 120 111.75 130 115.83 140 119.78 150 123.64 160 127.41 170 131.12 180 134.54 190 138.28 200 141.76 210 145.24 220 148.63 230 151.96 240 155.21 250 158.4 260 161.64 270 164.75 280 167.82 290 170.87 300 173.9 310 176.78 320 179.74 330 182.5 340 185.3 350 188.2 #CV 10 15 O.L. 20 O.L. 25 2567.55 30 2212.4 35 1966.19 40 1779.41 45 1638.42 50 1537.07 55 1475.09 60 1444.59 65 1431.21 70 1425.19 75 1422.12 80 1420.03 85 1418.32 90 1416.99 95 1415.84 100 1414.91 105 1413.98 110 1413.2 115 1412.52 120 1411.95 #End of manufacturer data file