#General information ITEM section %ITEM SERIAL NUMBER 20220900203522 Mfr serial number STN11536-03522 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 10/07/2001 PROBLEM NO PASSED YES Run number 20220900203522 #Test data Data section %DATA TEMPERATURE (C) 25 I_LEAK150V (microA) 0.13775 I_LEAK350V (microA) 0.217 Substr Origin 105 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 60 R Bias Upper (MOhm) 1.4 R Bias Lower (MOhm) 1.15 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 42.81 20 60.55 30 69.14 40 76.37 50 82.92 60 89.63 70 96.02 80 102.04 90 107.69 100 113.11 110 118.31 120 123.37 130 128.09 140 133.06 150 137.75 160 142.37 170 146.9 180 151.34 190 155.75 200 160.04 210 164.32 220 168.56 230 172.7 240 176.87 250 181 260 184.9 270 189 280 193.2 290 196.7 300 200.1 310 203.6 320 207.1 330 210.7 340 214 350 217 #CV 10 15 O.L. 20 O.L. 25 2498.42 30 2153.61 35 1911.9 40 1734.27 45 1600.95 50 1509.59 55 1458.32 60 1435.05 65 1425.33 70 1420.66 75 1417.86 80 1415.84 85 1414.21 90 1412.9 95 1411.67 100 1410.54 105 1409.66 110 1408.86 115 1408.15 120 1407.38 #End of manufacturer data file