#General information ITEM section %ITEM SERIAL NUMBER 20220900204062 Mfr serial number STN11630-04062 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 30/07/2001 PROBLEM NO PASSED YES Run number 20220900204062 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.13105 I_LEAK350V (microA) 0.2119 Substr Origin 114 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 60 R Bias Upper (MOhm) 1.35 R Bias Lower (MOhm) 1.12 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole 389 Pinhole 413 Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 37.71 20 54.15 30 62.58 40 68.88 50 74.37 60 80.72 70 87.59 80 94.04 90 100.06 100 105.73 110 111.15 120 116.44 130 121.39 140 126.22 150 131.05 160 135.65 170 140.15 180 144.67 190 149.04 200 153.33 210 157.67 220 161.86 230 165.98 240 170.04 250 174.14 260 178.11 270 181.9 280 185.9 290 189.6 300 193.4 310 197.2 320 200.8 330 204.5 340 208.2 350 211.9 #CV 10 15 O.L. 20 O.L. 25 2509.13 30 2168.53 35 1929.89 40 1751.25 45 1615.72 50 1518.1 55 1461.18 60 1436.18 65 1426.36 70 1421.83 75 1418.83 80 1416.96 85 1415.58 90 1414.3 95 1413.14 100 1412.17 105 1411.27 110 1410.48 115 1409.77 120 1408.98 #End of manufacturer data file