#General information ITEM section %ITEM SERIAL NUMBER 20220900204242 Mfr serial number STN11638-04242 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 09/08/2001 PROBLEM NO PASSED YES Run number 20220900204242 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.17403 I_LEAK350V (microA) 0.301 Substr Origin 120 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 293 Vdep (V) 60 R Bias Upper (MOhm) 1.45 R Bias Lower (MOhm) 1.23 #Comment section %COMMENT Al remainder between 339ch. and 340ch. #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 54.61 20 77.53 30 88.77 40 97.22 50 104.87 60 112.72 70 120.39 80 127.56 90 134.33 100 141.23 110 148.87 120 154.8 130 161 140 166.97 150 174.03 160 181.1 170 188.8 180 196.6 190 205.1 200 212.8 210 221.2 220 228.9 230 235.7 240 241.4 250 245.5 260 252.4 270 259.4 280 265 290 270.8 300 278 310 283 320 287.8 330 293.1 340 298.1 350 301 #CV 10 15 O.L. 20 O.L. 25 2535.29 30 2186.2 35 1942.92 40 1758.2 45 1618.15 50 1515.08 55 1451.3 60 1422.46 65 1411.47 70 1406.57 75 1403.85 80 1401.94 85 1400.36 90 1399.09 95 1398.13 100 1397.12 105 1396.35 110 1394.36 115 1393.78 120 1393.13 #End of manufacturer data file