#General information ITEM section %ITEM SERIAL NUMBER 20220900205174 Mfr serial number STN11934-05174 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 24/09/2001 PROBLEM NO PASSED YES Run number 20220900205174 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.11205 I_LEAK350V (microA) 0.17287 Substr Origin 151 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 55 R Bias Upper (MOhm) 1.4 R Bias Lower (MOhm) 1.31 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 35.51 20 50.09 30 57.22 40 62.68 50 68.36 60 73.93 70 79.12 80 83.96 90 88.46 100 92.76 110 96.87 120 100.87 130 104.66 140 108.35 150 112.05 160 115.56 170 119.02 180 122.28 190 125.78 200 129.01 210 132.27 220 135.42 230 138.53 240 141.65 250 144.74 260 147.75 270 150.76 280 153.74 290 156.61 300 159.44 310 162.24 320 164.83 330 167.5 340 170.25 350 172.87 #CV 10 15 O.L. 20 2798.84 25 2305.41 30 1991.05 35 1770.22 40 1612.35 45 1508.53 50 1454.56 55 1431.92 60 1423.32 65 1419.34 70 1416.97 75 1415.18 80 1413.77 85 1412.62 90 1411.64 95 1410.74 100 1409.94 105 1409.22 110 1408.7 115 1408.18 120 1407.64 #End of manufacturer data file