#General information ITEM section %ITEM SERIAL NUMBER 20220900205216 Mfr serial number STN11935-05216 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 25/09/2001 PROBLEM NO PASSED YES Run number 20220900205216 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.11396 I_LEAK350V (microA) 0.17742 Substr Origin 147 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 291 Vdep (V) 70 R Bias Upper (MOhm) 1.46 R Bias Lower (MOhm) 1.27 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 36.51 20 51.56 30 59.3 40 65.33 50 70.71 60 75.91 70 80.84 80 85.71 90 90.28 100 94.67 110 98.84 120 102.87 130 106.72 140 110.42 150 113.96 160 117.76 170 121.26 180 124.81 190 128.22 200 131.6 210 135.02 220 138.26 230 141.47 240 144.54 250 147.61 260 150.72 270 153.79 280 156.89 290 159.87 300 162.87 310 165.84 320 168.73 330 171.63 340 174.54 350 177.42 #CV 10 15 O.L. 20 O.L. 25 2781.56 30 2395.46 35 2126.08 40 1922.41 45 1766.41 50 1643.46 55 1546.18 60 1477.86 65 1437.93 70 1418.46 75 1409.76 80 1405.65 85 1403.19 90 1401.59 95 1400.38 100 1399.32 105 1398.59 110 1397.9 115 1397.37 120 1396.83 #End of manufacturer data file