#General information ITEM section %ITEM SERIAL NUMBER 20220900205226 Mfr serial number STN11935-05226 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 25/09/2001 PROBLEM NO PASSED YES Run number 20220900205226 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.11565 I_LEAK350V (microA) 0.17842 Substr Origin 147 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 70 R Bias Upper (MOhm) 1.46 R Bias Lower (MOhm) 1.27 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole 378 Pinhole 395 Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 35.16 20 49.49 30 57.22 40 63.35 50 69.18 60 74.81 70 80.12 80 85.31 90 90.28 100 94.98 110 99.47 120 103.8 130 107.82 140 111.75 150 115.65 160 119.17 170 122.97 180 126.57 190 130.04 200 133.44 210 136.82 220 140.1 230 143.34 240 146.52 250 149.69 260 152.74 270 155.76 280 158.74 290 161.6 300 164.49 310 167.37 320 170.18 330 172.95 340 175.73 350 178.42 #CV 10 15 O.L. 20 O.L. 25 2855.85 30 2457.78 35 2179.87 40 1970.73 45 1810.77 50 1684.27 55 1582.58 60 1507.16 65 1458.77 70 1432.85 75 1420.82 80 1415.45 85 1412.71 90 1410.97 95 1409.69 100 1408.67 105 1407.82 110 1407.2 115 1406.54 120 1405.92 #End of manufacturer data file