#General information ITEM section %ITEM SERIAL NUMBER 20220900205234 Mfr serial number STN11936-05234 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 25/09/2001 PROBLEM NO PASSED YES Run number 20220900205234 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.09794 I_LEAK350V (microA) 0.14591 Substr Origin 147 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 291 Vdep (V) 70 R Bias Upper (MOhm) 1.36 R Bias Lower (MOhm) 1.21 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 31.56 20 43.89 30 50.47 40 55.71 50 60.37 60 64.64 70 68.98 80 73.27 90 77.42 100 81.2 110 84.86 120 88.36 130 91.63 140 94.8 150 97.94 160 100.9 170 103.74 180 106.6 190 109.32 200 111.96 210 114.51 220 117.09 230 119.53 240 121.93 250 124.34 260 126.65 270 128.91 280 131.19 290 133.38 300 135.54 310 137.7 320 139.76 330 141.83 340 143.93 350 145.91 #CV 10 15 O.L. 20 O.L. 25 2809.31 30 2421.25 35 2151.27 40 1946.64 45 1789.58 50 1665.58 55 1567.16 60 1495.9 65 1451.62 70 1428.89 75 1418.6 80 1413.97 85 1411.24 90 1409.56 95 1408.25 100 1407.06 105 1406.11 110 1405.45 115 1404.77 120 1404.07 #End of manufacturer data file