#General information ITEM section %ITEM SERIAL NUMBER 20220900205242 Mfr serial number STN11936-05242 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 25/09/2001 PROBLEM NO PASSED YES Run number 20220900205242 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.10258 I_LEAK350V (microA) 0.15464 Substr Origin 147 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 70 R Bias Upper (MOhm) 1.36 R Bias Lower (MOhm) 1.21 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole 381 Pinhole 382 Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 31.87 20 44.51 30 51.33 40 56.95 50 62.23 60 67.16 70 71.86 80 76.37 90 80.7 100 84.76 110 88.65 120 92.37 130 95.87 140 99.25 150 102.58 160 105.63 170 108.88 180 111.99 190 114.86 200 117.67 210 120.39 220 123.1 230 125.73 240 128.37 250 130.99 260 133.5 270 136.02 280 138.49 290 140.9 300 143.28 310 145.63 320 147.94 330 150.15 340 152.45 350 154.64 #CV 10 15 O.L. 20 O.L. 25 2831.59 30 2439.46 35 2166.21 40 1959.72 45 1801.34 50 1676.22 55 1575.9 60 1502.12 65 1455.7 70 1431.57 75 1420.51 80 1415.34 85 1412.67 90 1410.77 95 1409.5 100 1408.36 105 1407.52 110 1406.68 115 1406.08 120 1405.42 #End of manufacturer data file