#General information ITEM section %ITEM SERIAL NUMBER 20220900205261 Mfr serial number STN11936-05261 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 25/09/2001 PROBLEM NO PASSED YES Run number 20220900205261 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.09541 I_LEAK350V (microA) 0.14401 Substr Origin 149 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 288 Vdep (V) 70 R Bias Upper (MOhm) 1.36 R Bias Lower (MOhm) 1.21 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 30.09 20 41.67 30 47.9 40 53.31 50 58.32 60 62.74 70 66.89 80 71.01 90 74.97 100 78.76 110 82.22 120 85.85 130 89.11 140 92.27 150 95.41 160 98.37 170 101.25 180 104.14 190 106.86 200 109.56 210 112.24 220 114.77 230 117.23 240 119.67 250 122.12 260 124.47 270 126.81 280 129.12 290 131.33 300 133.52 310 135.71 320 137.82 330 139.9 340 142 350 144.01 #CV 10 15 O.L. 20 O.L. 25 2876.02 30 2476.05 35 2197.16 40 1988.53 45 1828.1 50 1700.95 55 1598 60 1520.16 65 1468.35 70 1439.78 75 1426.53 80 1420.48 85 1417.52 90 1415.72 95 1414.33 100 1413.28 105 1412.29 110 1411.6 115 1410.97 120 1410.37 #End of manufacturer data file