#General information ITEM section %ITEM SERIAL NUMBER 20220900205663 Mfr serial number STN12031-05663 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 30/10/2001 PROBLEM NO PASSED YES Run number 20220900205663 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.17156 I_LEAK350V (microA) 0.2599 Substr Origin 165 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 55 R Bias Upper (MOhm) 1.49 R Bias Lower (MOhm) 1.35 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 48.53 20 69.25 30 79.75 40 88.43 50 97.94 60 106.72 70 114.93 80 122.69 90 130.18 100 137.42 110 144.3 120 150.93 130 158.12 140 164.85 150 171.56 160 178.19 170 184.8 180 191.5 190 198.1 200 204.1 210 210.5 220 216 230 221.6 240 227.4 250 232.7 260 238 270 242.7 280 246.6 290 249.7 300 252.1 310 254.1 320 255.7 330 257.2 340 258.6 350 259.9 #CV 10 15 O.L. 20 2826.69 25 2326.06 30 2005.71 35 1781.21 40 1621.8 45 1517.94 50 1462.1 55 1436.88 60 1426.85 65 1422.52 70 1419.95 75 1418.29 80 1416.84 85 1415.77 90 1414.99 95 1414.06 100 1413.26 105 1412.72 110 1412.41 115 1411.94 120 1411.37 #End of manufacturer data file