#General information ITEM section %ITEM SERIAL NUMBER 20220900205669 Mfr serial number STN12031-05669 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 30/10/2001 PROBLEM NO PASSED YES Run number 20220900205669 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.139 I_LEAK350V (microA) 0.2223 Substr Origin 165 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 55 R Bias Upper (MOhm) 1.49 R Bias Lower (MOhm) 1.35 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 40.3 20 57.85 30 66.13 40 72.75 50 79.92 60 87.21 70 94.07 80 100.51 90 106.62 100 112.49 110 118.04 120 123.44 130 128.8 140 133.95 150 139 160 143.91 170 148.83 180 153.55 190 158.24 200 162.54 210 167.49 220 171.92 230 176.35 240 180.79 250 185.1 260 189.4 270 193.4 280 197.3 290 201.3 300 205 310 208.7 320 212.2 330 215.8 340 219.2 350 222.3 #CV 10 15 O.L. 20 2831.16 25 2330.49 30 2010.51 35 1786.15 40 1626.76 45 1522.92 50 1466.69 55 1440.71 60 1430.21 65 1425.37 70 1422.71 75 1420.93 80 1419.41 85 1418.19 90 1417.16 95 1416.39 100 1415.65 105 1414.8 110 1414.3 115 1413.76 120 1413.13 #End of manufacturer data file