#General information ITEM section %ITEM SERIAL NUMBER 20220900205671 Mfr serial number STN12031-05671 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 30/10/2001 PROBLEM NO PASSED YES Run number 20220900205671 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.12135 I_LEAK350V (microA) 0.1918 Substr Origin 165 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 55 R Bias Upper (MOhm) 1.49 R Bias Lower (MOhm) 1.35 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 37.14 20 53.61 30 61.38 40 67.17 50 72.73 60 78.37 70 84.08 80 89.55 90 94.54 100 99.54 110 104.1 120 108.55 130 112.97 140 117.19 150 121.35 160 125.38 170 129.42 180 133.31 190 137.13 200 140.9 210 144.66 220 148.27 230 151.83 240 155.35 250 158.86 260 162.38 270 165.77 280 169.12 290 172.44 300 175.78 310 179.09 320 182.3 330 185.4 340 188.6 350 191.8 #CV 10 15 O.L. 20 2864.55 25 2357.1 30 2034.52 35 1807.81 40 1645.39 45 1536.1 50 1474.83 55 1445.77 60 1433.93 65 1428.66 70 1425.86 75 1423.74 80 1422.25 85 1421.02 90 1419.93 95 1418.84 100 1418.01 105 1417.28 110 1416.5 115 1416.07 120 1415.37 #End of manufacturer data file