#General information ITEM section %ITEM SERIAL NUMBER 20220900205720 Mfr serial number STN12035-05720 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 20/10/2001 PROBLEM NO PASSED YES Run number 20220900205720 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.119 I_LEAK350V (microA) 0.17699 Substr Origin 170 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 75 R Bias Upper (MOhm) 1.34 R Bias Lower (MOhm) 1.2 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 40 20 55.19 30 63.69 40 70.94 50 77.22 60 82.39 70 87.06 80 91.63 90 96.08 100 100.33 110 104.33 120 108.15 130 111.93 140 115.51 150 119 160 122.39 170 125.77 180 129 190 132.19 200 135.32 210 138.46 220 141.47 230 144.41 240 147.3 250 150.17 260 153.05 270 155.83 280 158.6 290 161.1 300 164.04 310 166.69 320 169.29 330 171.9 340 174.47 350 176.99 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2595.41 35 2303.3 40 2082.57 45 1913.67 50 1779.69 55 1669.6 60 1581.62 65 1515.72 70 1472.72 75 1448.52 80 1435.95 85 1429.96 90 1426.94 95 1425.12 100 1423.74 105 1422.63 110 1421.85 115 1421.04 120 1420.42 #End of manufacturer data file