#General information ITEM section %ITEM SERIAL NUMBER 20220900205803 Mfr serial number STN12036-05803 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 30/10/2001 PROBLEM NO PASSED YES Run number 20220900205803 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.13645 I_LEAK350V (microA) 0.2104 Substr Origin 165 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 65 R Bias Upper (MOhm) 1.46 R Bias Lower (MOhm) 1.29 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 42.52 20 60.52 30 70 40 77.16 50 83.47 60 89.99 70 96.49 80 102.53 90 108.13 100 113.23 110 118.29 120 123.03 130 127.7 140 132.13 150 136.45 160 140.64 170 144.83 180 148.86 190 152.83 200 156.75 210 160.68 220 164.48 230 168.26 240 171.98 250 175.68 260 179.4 270 183 280 186.5 290 190 300 193.4 310 196.9 320 200.2 330 203.6 340 207.1 350 210.4 #CV 10 15 O.L. 20 O.L. 25 2682.57 30 2310.35 35 2050.86 40 1856.26 45 1708.72 50 1595.89 55 1516 60 1468.47 65 1444.87 70 1434.25 75 1429.1 80 1426.33 85 1424.3 90 1422.78 95 1421.47 100 1420.24 105 1419.38 110 1418.42 115 1417.6 120 1416.89 #End of manufacturer data file