#General information ITEM section %ITEM SERIAL NUMBER 20220900205806 Mfr serial number STN12036-05806 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 30/10/2001 PROBLEM NO PASSED YES Run number 20220900205806 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.17193 I_LEAK350V (microA) 0.2834 Substr Origin 175 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 291 Vdep (V) 65 R Bias Upper (MOhm) 1.46 R Bias Lower (MOhm) 1.29 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 48.99 20 70.75 30 83.42 40 92.08 50 100.79 60 109.28 70 117.33 80 124.99 90 132.31 100 139.34 110 146.04 120 152.61 130 159.21 140 165.57 150 171.93 160 178.2 170 184.5 180 190.7 190 196.8 200 202.8 210 208.9 220 215.2 230 221.4 240 227.3 250 233.5 260 239.5 270 245 280 250.1 290 255.7 300 261 310 265.4 320 270.7 330 275.2 340 279.6 350 283.4 #CV 10 15 O.L. 20 O.L. 25 2725.83 30 2346.91 35 2082.64 40 1884.88 45 1733.37 50 1615.85 55 1527.81 60 1471.69 65 1441.92 70 1428.02 75 1421.46 80 1417.99 85 1415.86 90 1414.22 95 1412.73 100 1411.63 105 1410.56 110 1409.64 115 1408.91 120 1408.12 #End of manufacturer data file