#General information ITEM section %ITEM SERIAL NUMBER 20220900205862 Mfr serial number STN12037-05862 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 29/10/2001 PROBLEM NO PASSED YES Run number 20220900205862 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.11475 I_LEAK350V (microA) 0.16471 Substr Origin 177 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 286 Vdep (V) 80 R Bias Upper (MOhm) 1.58 R Bias Lower (MOhm) 1.24 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 39.19 20 54.59 30 63.05 40 69.68 50 75.45 60 80.59 70 85.14 80 89.46 90 93.64 100 97.61 110 101.33 120 104.94 130 108.3 140 111.43 150 114.75 160 117.81 170 120.78 180 123.72 190 126.51 200 129.27 210 132.01 220 134.66 230 137.23 240 139.75 250 142.29 260 144.69 270 147 280 149.34 290 151.61 300 153.84 310 156.1 320 158.27 330 160.43 340 162.62 350 164.71 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2684.05 35 2381.69 40 2156 45 1980.56 50 1841.1 55 1726.03 60 1631.69 65 1557.02 70 1503.75 75 1470.41 80 1451.7 85 1442.08 90 1437.2 95 1434.46 100 1432.62 105 1431.39 110 1430.35 115 1429.44 120 1428.5 #End of manufacturer data file