#General information ITEM section %ITEM SERIAL NUMBER 20220900205896 Mfr serial number STN12137-05896 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 30/10/2001 PROBLEM NO PASSED YES Run number 20220900205896 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.12803 I_LEAK350V (microA) 0.1939 Substr Origin 176 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 80 R Bias Upper (MOhm) 1.39 R Bias Lower (MOhm) 1.3 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 38.21 20 54.19 30 63.26 40 70.97 50 77.75 60 84.02 70 89.78 80 95.34 90 100.72 100 105.86 110 110.73 120 115.32 130 119.54 140 123.93 150 128.03 160 132.03 170 135.87 180 139.62 190 143.3 200 146.91 210 150.42 220 153.87 230 157.24 240 160.59 250 163.87 260 167.08 270 170.27 280 173.41 290 176.48 300 179.49 310 182.4 320 185.3 330 188.3 340 191.1 350 193.9 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2634.37 35 2335.51 40 2112.02 45 1940.63 50 1803.81 55 1691.68 60 1600.08 65 1528.54 70 1478.09 75 1446.94 80 1429.65 85 1421.13 90 1416.91 95 1414.56 100 1413.14 105 1412 110 1411.08 115 1410.36 120 1409.43 #End of manufacturer data file