#General information ITEM section %ITEM SERIAL NUMBER 20220900205936 Mfr serial number STN12138-05936 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 31/10/2001 PROBLEM NO PASSED YES Run number 20220900205936 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.13783 I_LEAK350V (microA) 0.2052 Substr Origin 175 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 80 R Bias Upper (MOhm) 1.47 R Bias Lower (MOhm) 1.28 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 43.12 20 62.2 30 72.26 40 80.14 50 87.59 60 94.18 70 99.81 80 105.13 90 110.41 100 115.52 110 120.39 120 125.01 130 129.43 140 133.68 150 137.83 160 141.85 170 145.77 180 149.61 190 153.35 200 156.8 210 160.62 220 164.15 230 167.63 240 171.08 250 174.42 260 177.75 270 180.9 280 184.1 290 187.2 300 190.3 310 193.3 320 196.3 330 199.3 340 202.3 350 205.2 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2747.76 35 2433.33 40 2200.25 45 2015.99 50 1870.57 55 1751.12 60 1652.71 65 1571.28 70 1508.18 75 1464.83 80 1438.08 85 1423.47 90 1416.08 95 1412.26 100 1410.02 105 1408.56 110 1407.52 115 1406.6 120 1405.66 #End of manufacturer data file