#General information ITEM section %ITEM SERIAL NUMBER 20220900205947 Mfr serial number STN12138-05947 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 31/10/2001 PROBLEM NO PASSED YES Run number 20220900205947 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.15542 I_LEAK350V (microA) 0.2396 Substr Origin 176 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 287 Vdep (V) 80 R Bias Upper (MOhm) 1.47 R Bias Lower (MOhm) 1.28 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 46.88 20 67.67 30 79.06 40 88.05 50 96.68 60 104.31 70 111.05 80 117.45 90 123.62 100 129.53 110 135.16 120 140.62 130 145.75 140 150.73 150 155.42 160 160.45 170 165.12 180 169.8 190 174.32 200 178.78 210 183.2 220 187.5 230 191.7 240 195.9 250 200.2 260 204.3 270 208.4 280 212.4 290 216.4 300 220.4 310 224.3 320 228.1 330 231.9 340 235.7 350 239.6 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2703.73 35 2395.45 40 2166.32 45 1985.91 50 1843.26 55 1726.46 60 1630.99 65 1554.86 70 1499.99 75 1465.45 80 1445.81 85 1435.62 90 1430.43 95 1427.59 100 1425.81 105 1424.46 110 1423.53 115 1422.66 120 1421.76 #End of manufacturer data file