#General information ITEM section %ITEM SERIAL NUMBER 20220900206156 Mfr serial number STN12030-06156 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 12/11/2001 PROBLEM NO PASSED YES Run number 20220900206156 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.11694 I_LEAK350V (microA) 0.17764 Substr Origin 159 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 70 R Bias Upper (MOhm) 1.29 R Bias Lower (MOhm) 1.03 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 38.05 20 50.09 30 57.54 40 63.57 50 69.06 60 74.27 70 79.7 80 85.35 90 90.82 100 95.86 110 100.54 120 104.97 130 109.14 140 113.14 150 116.94 160 120.74 170 124.39 180 127.91 190 131.35 200 134.7 210 137.98 220 141.17 230 144.29 240 147.39 250 150.44 260 153.4 270 156.31 280 159.16 290 161.96 300 164.71 310 167.36 320 170 330 172.61 340 175.16 350 177.64 #CV 10 15 O.L. 20 O.L. 25 2838.07 30 2443.66 35 2168.33 40 1962.32 45 1804.05 50 1678.4 55 1579.43 60 1507.97 65 1463.2 70 1439.4 75 1428.19 80 1422.81 85 1419.9 90 1417.91 95 1416.45 100 1415.29 105 1414.37 110 1413.57 115 1412.84 120 1412.29 #End of manufacturer data file