#General information ITEM section %ITEM SERIAL NUMBER 20220900206184 Mfr serial number STN12030-06184 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 12/11/2001 PROBLEM NO PASSED YES Run number 20220900206184 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.12485 I_LEAK350V (microA) 0.1927 Substr Origin 158 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 70 R Bias Upper (MOhm) 1.29 R Bias Lower (MOhm) 1.03 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 38.77 20 51.18 30 59 40 65.74 50 71.77 60 77.38 70 83.44 80 89.71 90 95.76 100 101.38 110 106.58 120 111.48 130 116.13 140 120.56 150 124.85 160 129.03 170 133.04 180 136.85 190 140.78 200 144.55 210 148.23 220 151.8 230 155.32 240 158.78 250 162.15 260 165.46 270 168.76 280 171.97 290 175.14 300 178.24 310 181.1 320 184.1 330 187 340 189.8 350 192.7 #CV 10 15 O.L. 20 O.L. 25 2858.3 30 2462.45 35 2186.05 40 1979.05 45 1819.85 50 1693.3 55 1592.12 60 1517.16 65 1468.41 70 1441.59 75 1428.73 80 1422.82 85 1419.64 90 1417.54 95 1416.13 100 1414.99 105 1414.07 110 1413.26 115 1412.53 120 1411.75 #End of manufacturer data file