#General information ITEM section %ITEM SERIAL NUMBER 20220900206427 Mfr serial number STN12162-06427 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 29/11/2001 PROBLEM NO PASSED YES Run number 20220900206427 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.09291 I_LEAK350V (microA) 0.13728 Substr Origin 186 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 75 R Bias Upper (MOhm) 1.47 R Bias Lower (MOhm) 1.31 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short 147 Short 148 Short 149 Short 150 Short 151 Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 29.9 20 41.38 30 47.78 40 53.19 50 58.05 60 62.32 70 66.24 80 70.13 90 73.9 100 77.49 110 80.88 120 84.09 130 87.14 140 90.07 150 92.91 160 95.67 170 98.32 180 100.91 190 103.45 200 105.9 210 108.3 220 110.64 230 112.94 240 115.19 250 117.41 260 119.54 270 121.67 280 123.77 290 125.82 300 127.85 310 129.79 320 131.72 330 133.65 340 135.48 350 137.28 #CV 10 15 O.L. 20 O.L. 25 2957.44 30 2550.18 35 2267.45 40 2053.11 45 1888.61 50 1758.38 55 1651.89 60 1567.9 65 1506.41 70 1467.41 75 1445.93 80 1435.28 85 1429.98 90 1427.2 95 1425.51 100 1424.13 105 1422.99 110 1422.08 115 1421.21 120 1420.36 #End of manufacturer data file