#General information ITEM section %ITEM SERIAL NUMBER 20220900206622 Mfr serial number STN12261-06622 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 11/12/2001 PROBLEM NO PASSED YES Run number 20220900206622 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.10823 I_LEAK350V (microA) 0.16577 Substr Origin 184 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 284 Vdep (V) 55 R Bias Upper (MOhm) 1.47 R Bias Lower (MOhm) 1.33 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole 525 Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 19.856 20 47.37 30 54.02 40 59.05 50 63.85 60 69.38 70 74.9 80 79.99 90 84.67 100 89.07 110 93.26 120 97.17 130 101 140 104.63 150 108.23 160 111.72 170 114.83 180 118.28 190 121.49 200 124.66 210 127.7 220 130.74 230 133.67 240 136.61 250 139.45 260 142.38 270 145.06 280 147.74 290 150.42 300 153.06 310 155.71 320 158.28 330 160.81 340 163.29 350 165.77 #CV 10 15 O.L. 20 2799.61 25 2307.17 30 1994.1 35 1773.12 40 1615.68 45 1510.48 50 1456.61 55 1435.44 60 1427.5 65 1423.56 70 1421.03 75 1419.19 80 1417.63 85 1416.36 90 1415.24 95 1414.22 100 1413.32 105 1412.46 110 1411.81 115 1411.26 120 1410.63 #End of manufacturer data file