#General information ITEM section %ITEM SERIAL NUMBER 20220900206733 Mfr serial number STN12269-06733 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 13/12/2001 PROBLEM NO PASSED YES Run number 20220900206733 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.09648 I_LEAK350V (microA) 0.14048 Substr Origin 194 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 291 Vdep (V) 70 R Bias Upper (MOhm) 1.4 R Bias Lower (MOhm) 1.25 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole 401 Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 32.27 20 43.72 30 50.12 40 55.21 50 60.03 60 64.54 70 68.97 80 73.14 90 77.15 100 80.85 110 84.25 120 87.5 130 90.66 140 93.63 150 96.48 160 99.22 170 101.96 180 104.51 190 107.03 200 109.53 210 111.93 220 114.26 230 116.46 240 118.7 250 120.83 260 123.06 270 125.14 280 127.23 290 129.22 300 131.28 310 133.21 320 135.07 330 136.9 340 138.74 350 140.48 #CV 10 15 O.L. 20 O.L. 25 2729.65 30 2356 35 2094.98 40 1898.94 45 1748.79 50 1632.62 55 1545.56 60 1487.59 65 1453.24 70 1435.27 75 1426.62 80 1422.29 85 1419.9 90 1418.18 95 1416.97 100 1415.89 105 1414.95 110 1414.11 115 1413.4 120 1412.73 #End of manufacturer data file