#General information ITEM section %ITEM SERIAL NUMBER 20220900207508 Mfr serial number STN12413-07508 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 29/01/2002 PROBLEM NO PASSED YES Run number 20220900207508 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.08756 I_LEAK350V (microA) 0.12672 Substr Origin 216 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 75 R Bias Upper (MOhm) 1.44 R Bias Lower (MOhm) 1.35 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 30.12 20 40.41 30 46.27 40 50.99 50 55.26 60 59.31 70 63.18 80 66.89 90 70.45 100 73.71 110 76.77 120 79.64 130 82.38 140 85.02 150 87.56 160 90.02 170 92.31 180 94.6 190 96.81 200 99.04 210 101.15 220 103.25 230 105.21 240 107.22 250 109.16 260 111.06 270 112.88 280 114.74 290 116.59 300 118.37 310 120.1 320 121.78 330 123.48 340 125.08 350 126.72 #CV 10 15 O.L. 20 O.L. 25 2894.21 30 2502.22 35 2227.34 40 2020.35 45 1861.49 50 1733.22 55 1629.23 60 1548.79 65 1493.88 70 1461.19 75 1444.12 80 1435.84 85 1431.84 90 1429.51 95 1427.9 100 1426.63 105 1425.57 110 1424.75 115 1423.94 120 1423.17 #End of manufacturer data file