#General information ITEM section %ITEM SERIAL NUMBER 20220900207611 Mfr serial number STN12539-07611 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 25/01/2002 PROBLEM NO PASSED YES Run number 20220900207611 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.09174 I_LEAK350V (microA) 0.1336 Substr Origin 221 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 80 R Bias Upper (MOhm) 1.54 R Bias Lower (MOhm) 1.34 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 30.42 20 41.64 30 47.87 40 52.78 50 57.19 60 61.52 70 65.54 80 69.43 90 73.21 100 76.78 110 80.11 120 83.22 130 86.22 140 89.01 150 91.74 160 94.38 170 96.9 180 99.37 190 101.76 200 104.09 210 106.37 220 108.57 230 110.76 240 112.88 250 114.93 260 117 270 119 280 120.97 290 122.91 300 124.84 310 126.62 320 128.38 330 130.23 340 131.94 350 133.6 #CV 10 15 O.L. 20 O.L. 25 2997.23 30 2588.17 35 2300.98 40 2085.77 45 1919.8 50 1786.34 55 1677.24 60 1588.23 65 1519.77 70 1472.86 75 1444.58 80 1429.26 85 1421.42 90 1417.4 95 1414.93 100 1413.44 105 1412.13 110 1411.19 115 1410.21 120 1409.5 #End of manufacturer data file