#General information ITEM section %ITEM SERIAL NUMBER 20220900207622 Mfr serial number STN12539-07622 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 25/01/2002 PROBLEM NO PASSED YES Run number 20220900207622 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.09224 I_LEAK350V (microA) 0.13324 Substr Origin 224 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 292 Vdep (V) 85 R Bias Upper (MOhm) 1.54 R Bias Lower (MOhm) 1.34 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 30.63 20 42.35 30 48.89 40 54.12 50 59.02 60 63.51 70 67.29 80 70.86 90 74.32 100 77.66 110 80.91 120 83.93 130 86.78 140 89.58 150 92.24 160 94.76 170 97.24 180 99.68 190 101.98 200 104.26 210 106.53 220 108.68 230 110.79 240 112.88 250 114.93 260 116.96 270 118.9 280 120.86 290 122.78 300 124.58 310 126.34 320 128.11 330 129.89 340 131.58 350 133.24 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2754.36 35 2446.94 40 2216.45 45 2038.3 50 1895.98 55 1778.57 60 1680.58 65 1598.69 70 1532.54 75 1482.89 80 1448.93 85 1427.63 90 1415.47 95 1409.1 100 1405.56 105 1403.37 110 1401.92 115 1401.1 120 1400.16 #End of manufacturer data file