#General information ITEM section %ITEM SERIAL NUMBER 20220900208069 Mfr serial number STN12559-08069 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 21/02/2002 PROBLEM NO PASSED YES Run number 20220900208069 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.11058 I_LEAK350V (microA) 0.16171 Substr Origin 230 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 292 Vdep (V) 80 R Bias Upper (MOhm) 1.55 R Bias Lower (MOhm) 1.38 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 36.41 20 50.19 30 58.02 40 64.12 50 69.47 60 74.56 70 79.38 80 83.93 90 88.42 100 92.7 110 96.62 120 100.42 130 103.94 140 107.28 150 110.58 160 113.77 170 116.75 180 119.75 190 122.66 200 125.44 210 128.19 220 130.91 230 133.49 240 136.1 250 138.61 260 141.09 270 143.56 280 145.94 290 148.31 300 150.69 310 153.01 320 155.26 330 157.49 340 159.59 350 161.71 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2664.94 35 2368.12 40 2145.04 45 1973.58 50 1836.26 55 1722.42 60 1629.06 65 1553.31 70 1496.69 75 1458.49 80 1435.45 85 1422.03 90 1415.34 95 1411.61 100 1409.25 105 1407.85 110 1406.54 115 1405.56 120 1404.98 #End of manufacturer data file