#General information ITEM section %ITEM SERIAL NUMBER 20220900208239 Mfr serial number STN12566-08239 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 23/02/2002 PROBLEM NO PASSED YES Run number 20220900208239 #Test data Data section %DATA TEMPERATURE (C) 28 I_LEAK150V (microA) 0.09948 I_LEAK350V (microA) 0.14999 Substr Origin 245 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 65 R Bias Upper (MOhm) 1.53 R Bias Lower (MOhm) 1.35 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 33.45 20 45.3 30 51.71 40 56.7 50 60.84 60 64.92 70 69.3 80 73.87 90 78.19 100 82.21 110 85.93 120 89.52 130 93.02 140 96.3 150 99.48 160 102.53 170 105.58 180 108.47 190 111.29 200 114.04 210 116.82 220 119.44 230 122.03 240 124.54 250 127.02 260 129.52 270 131.93 280 134.28 290 136.62 300 138.97 310 141.24 320 143.46 330 145.67 340 147.88 350 149.99 #CV 10 15 O.L. 20 O.L. 25 2695.14 30 2326.55 35 2068.34 40 1875.4 45 1728.95 50 1615.54 55 1534.34 60 1483.25 65 1455.4 70 1441.82 75 1435.11 80 1431.45 85 1429.05 90 1427.37 95 1425.96 100 1424.63 105 1423.42 110 1422.43 115 1421.58 120 1420.55 #End of manufacturer data file