#General information ITEM section %ITEM SERIAL NUMBER 20220900208281 Mfr serial number STN12613-08281 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 26/02/2002 PROBLEM NO PASSED YES Run number 20220900208281 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.08528 I_LEAK350V (microA) 0.1275 Substr Origin 246 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 286 Vdep (V) 55 R Bias Upper (MOhm) 1.56 R Bias Lower (MOhm) 1.27 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 19.196 20 38.71 30 43.87 40 47.94 50 51.85 60 55.8 70 59.64 80 63.42 90 67.03 100 70.5 110 73.71 120 76.77 130 79.7 140 82.54 150 85.28 160 87.93 170 90.4 180 92.91 190 95.33 200 97.68 210 99.99 220 102.23 230 104.45 240 106.61 250 108.74 260 110.79 270 112.78 280 114.77 290 116.75 300 118.65 310 120.46 320 122.29 330 124.05 340 125.81 350 127.5 #CV 10 15 O.L. 20 2780.62 25 2293.1 30 1979.88 35 1767.12 40 1621.16 45 1528.54 50 1477.91 55 1453.54 60 1442.9 65 1437.93 70 1435.03 75 1433.21 80 1431.75 85 1430.36 90 1429.34 95 1428.28 100 1427.32 105 1426.63 110 1425.82 115 1425.14 120 1424.44 #End of manufacturer data file