#General information ITEM section %ITEM SERIAL NUMBER 20220900208302 Mfr serial number STN12681-08302 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 27/02/2002 PROBLEM NO PASSED YES Run number 20220900208302 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.08574 I_LEAK350V (microA) 0.13128 Substr Origin 206 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 288 Vdep (V) 55 R Bias Upper (MOhm) 1.42 R Bias Lower (MOhm) 1.26 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 10.434 20 37.03 30 42.02 40 45.89 50 49.62 60 53.94 70 58.43 80 62.57 90 66.42 100 70.02 110 73.42 120 76.69 130 79.82 140 82.82 150 85.74 160 88.58 170 91.34 180 94.02 190 96.64 200 99.2 210 101.72 220 104.17 230 106.57 240 108.92 250 111.22 260 113.4 270 115.49 280 117.58 290 119.63 300 121.66 310 123.61 320 125.55 330 127.51 340 129.4 350 131.28 #CV 10 15 O.L. 20 2829.17 25 2336.27 30 2020.72 35 1802 40 1643.43 45 1533.62 50 1471.87 55 1445.28 60 1435.02 65 1430.3 70 1427.26 75 1425.36 80 1423.86 85 1422.52 90 1421.29 95 1420.17 100 1419.29 105 1418.44 110 1417.62 115 1417.06 120 1416.36 #End of manufacturer data file