#General information ITEM section %ITEM SERIAL NUMBER 20220900208781 Mfr serial number STN12628-08781 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 19/03/2001 PROBLEM NO PASSED YES Run number 20220900208781 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.12778 I_LEAK350V (microA) 0.1952 Substr Origin 245 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 291 Vdep (V) 70 R Bias Upper (MOhm) 1.65 R Bias Lower (MOhm) 1.51 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 41.19 20 56.87 30 65.9 40 73.35 50 79.45 60 84.73 70 89.89 80 95.18 90 100.52 100 105.65 110 110.46 120 115.06 130 119.28 140 123.67 150 127.78 160 131.76 170 135.55 180 139.34 190 143.04 200 146.7 210 150.22 220 153.73 230 157.16 240 160.57 250 163.91 260 167.21 270 170.46 280 173.67 290 176.85 300 179.99 310 183.2 320 186.3 330 189.3 340 192.3 350 195.2 #CV 10 15 O.L. 20 O.L. 25 2838.86 30 2450.35 35 2177.62 40 1973.08 45 1816.31 50 1692.09 55 1593.64 60 1520.89 65 1472.64 70 1444.45 75 1430.01 80 1422.98 85 1419.3 90 1417.09 95 1415.52 100 1414.17 105 1413.15 110 1412.16 115 1411.37 120 1410.42 #End of manufacturer data file